Siemens VSD Micro Master 440 (MM440) |
|
|
|
MM440 networked on Profibus-DP |
|
|
|
MM440 networked on Profibus-DP |
|
|
|
|
PDL Standalone for fix frequency application |
|
|
|
PDL Standalone for fix frequency application |
|
|
|
PDL standalone for flow control using 4-20ma and PID |
|
|
|
|
SEW Movitrac networked on Profibus-DP used for speed, level, and flow control |
|
|
|
SEW Movitrac networked on Profibus-D (close-up) |
|
|
|
SEW Movitrac networked on Profibus-DP used for speed, level, and flow control |
|
|
|
|
Stanalone Omron Sysdrive, used for pressure control |
|
|
|
Small Omron Sysdrive, used for conveyor speed control |
|
|
|
Stanalone Omron Sysdrive, used for pressure control |
|
|
|
We have been involved
in
the design and integration of
VSD solutions
for Positioning,
Speed, and Torque applications. No matter what brand or model, we can help you
to get the best benefits of your inverter using our experience and skills to
produce reliable and functional solutions. We can engineer standalone as well
as fully integrated VSD systems. Some recent projects are:
-
Position control via 4-20ma loop using Siemens Micro Master VSDs, S7 PLC,
High-Speed counter card, and encoders
-
Position control using proximity switches. Standalone PDL VSDs, not PLC
required
-
Conveyor speed control using SEW Movitrac VSDs. Set point and controls over
Profibus-DP. More than 60 VSDs in one network
-
Torque control using ABB VSDs on a mixing tank. Stand alone, not PLC required
-
Positioning with DC breaking for heavy trolley system. Using Micro Master
VSDs on Profibus-DP
-
Pressure control, using 4-20ma pressure sensor, S7 PLC, Omron Sysdrives, and
cascade PID loops.
-
Flow control, using ABB flow meters, Siemens S7 PLC, PID loops, and Toshiba
VSDs for a water treatment plant.
-
Level control, using SEW Movitrac VSDs, PID loops, and a S7 PLC
There are hundreds of applications where VSDs are required. Talk to us, we can
help to clarify your doubts.
Need more info? Contact us
|